Alarm System Removal


Overview

• Safe disconnection and physical removal of an existing domestic burglar-alarm system. Skill level: 4 / 5 (advanced DIYer comfortable with electrics). Typical duration: 2 – 3 hours.

Safety First

  1. Switch off the alarm’s fused spur or breaker and confirm power is dead.

  2. Disconnect the battery inside the control panel to prevent accidental siren activation.

  3. Use insulated screwdrivers/gloves when handling live-supply cables.

  4. Work from a stable ladder for bell-box removal; wear eye protection against dust.

  5. Warn household members the system will be out of service during removal.

Tools & Materials

Item

Purpose

Multimeter

Verify mains and DC are isolated

Insulated screwdrivers & side cutters

Remove terminals, cut cables

Step-ladder / extension ladder

Access bell-box at eaves

Cable connectors / Wago blocks

Make live cores safe in enclosure

Electrical tape & blanking plates

Insulate/cover redundant back-boxes

Polyfilla or filler & sandpaper

Patch drill holes after sensor removal

Cordless drill with masonry bits

Remove bell-box and cable clips

Dust sheet & vacuum

Collect plaster/brick dust

Step-by-Step

1. Isolate Power

Turn off the dedicated fused spur or MCB feeding the alarm panel. Confirm with a multimeter that both mains and battery outputs are dead. Why: Prevents shock and siren activation.

2. Notify Monitoring Centre (If Applicable)

Phone the ARC, quote your password, and request a “maintenance mode” or permanent cancellation. Why: Avoids false police call-outs.

Pro-tip: Obtain written confirmation to prevent ongoing monitoring charges.

3. Silence and Open the External Bell-Box

On a ladder, remove bell-box cover screws; unplug battery or disable tamper switch. Disconnect and cap the supply cable; remove the bell-box from the wall. Why: Stops the back-up siren sounding when power is cut.

4. Remove Control Panel & Battery

Undo securing screws, label mains feed and zone wires for clarity, then disconnect. Cut cables flush or terminate into Wago blocks and fit a blanking plate over the recessed box. Why: De-energises all system circuits.

5. De-commission Keypads and Sensors

Unscrew each device, disconnect wiring, then either pull cable back into ceiling void or cap ends. Fill fixing holes with filler; sand smooth once set. Why: Clears walls and makes cables safe.

6. Make Good Cables and Wall Surfaces

Tuck insulated cable ends into plaster behind blank plates. Patch, sand and lightly prime any larger chases or drilled holes. Why: Ensures no live or exposed copper and restores décor.

7. Final Electrical Check

Re-energise the consumer unit; verify fused spur remains off or removed. Use multimeter to ensure no voltage at any remaining cable ends. Why: Confirms complete isolation and safety.

Completion Checks

  • All bell-box, panel, sensors and keypads physically removed.

  • No exposed copper; unused cables are insulated and secure.

  • Wall surfaces filled, sanded and ready for repaint.

  • Monitoring contract confirmed cancelled.

  • Consumer-unit circuits labelled accurately.

When to call a pro instead

If the system is linked to police response, contains hard-wired smoke detectors, integrates with smart-home or fire-alarm panels, or the bell-box is positioned where ladders/scaffolding are unsafe, hire an SSAIB/NSI-approved security engineer to de-commission it compliantly and issue the necessary paperwork.